PROTECTO 401 VS. RESIN RICH EPOXY

Test Protecto 401

Results

Resin Rich Epoxy
UNDERCUTTING RESISTANCE

Alternate wet/dry immersion

(5%NaCl,flowing,aerated,120 °F,

wet 1 hour followed by dry 1 hour- 12 cycles/day) Duration-1 year

Passed No undercutting at exposed edges Failed Severe undercutting at exposed edges (average 15% undercutting)
WEATHERING

1 Year direct exposure

Ductile Iron Pipe coupons with cut edges

No Undercutting Undercutting with 50% disbondment failure
20% SULFURIC ACID RESISTANCE
Rated using ASTM D-714 (Measure of Resistance to low PH sewer)
2 years immersion.
No effect
30 days spot test
Irreversible chemical change. Coating softened and swells. Coating turns brown.
IMPACT RESISTANCE
on ductile iron pipe
ASTM G-14
72 in/lbs. 40 in/lbs.
RECOATABILITY
(Important to prevent delamination between coats and repair.)
Indefinitely recoatable
with itself without roughening of existing coats.
Not recoatable
after 24 hour cure without roughening of the surface.
SALT SPRAY
ASTM B-117-85
5% SALT @ 98 °F
2.0 years
No undercutting at scribe.
1.7 months
0.25″ undercutting at scribe.
HOT WATER IMMERSION 2.0 years at 160 °F
No undercutting at scribe.
1.7 months at 140 °F
0.25″ undercutting at scribe.
NOTE:
All materials tested with an average film thickness of 40 mils on production lined ductile iron pipe.

 

PROTECTO 401 VS. RESIN RICH EPOXY

Protecto 401 Ceramic Epoxy Resin Rich Epoxy
Epoxy Resin 100% Novalac Epoxy1 50% Novalac Epoxy1

50% Non-Novalac Epoxy1

Film Build 60 mils minimum in one coat3 12 mils maximum per coat2
Recoatability Recoatable indefinitely with itself3 Not recoatable after 24 hours @70ËšF,

Less recoat time at higher temperature2

Ductile Iron Pipe Lined

History/Usage

25 years/40 million linear feet Unknown
 

INDEPENDENT TESTING:

IMPACT RESISTANCE

ASTM D-2794-93

72 in./lbs.4, 5 60 in./lbs.5
ABRASION RESISTANCE

ASTM D-4060-90

H-18 wheel 1,000 gram load for 1,000 cycles

.39 Average weight loss4,6 .58 Average weight loss6
PERMEABILITY

ASTM E-96-66

0.00 4,7 No independent data
VACUUM TESTING

ASTM F-1476-95a

25 inches mercury4,6 No independent data
STANDARD TEST METHOD

For Effect of Household Chemicals

ASTM D-1308

Passed4,7 No independent data
RESISTANCE TO CATHODIC DISBONDMENT

By The Attached Cell Method 45 Days

ASTM G-95

0.5 mm4,7 No independent data
SALT FOG TESTING

ASTM B-117

0.0 undercutting4,7 No independent test data

1 Material safety data sheet published by the manufacturer.

2 Data sheet published by Superior Products for SP-2000.

3 Quality control records for Protecto 401 Ceramic Epoxy .

4 All test data on Protecto 401 Ceramic Epoxy as reported was produced by testing production-run ductile iron pipe.

5 Test commissioned by Superior Products.

6 Test commissioned by pipe manufacturer.

7 Test commissioned by manufacturer of Protecto 401 Ceramic Epoxy