TEST METHOD: ASTM D-1308
Standard Test Method for Effect of Household Chemicals on Clear and Pigmented Finishes. (Chemical Soak Test with Nine Test Solutions)
COATING SYSTEM:
PROTECTO 401â„¢ CERAMIC EPOXY Lining: Plant applied Protecto 401 lined ductile iron pipe (DIP) cut into 3 inch x 4 inch coupons.
TEST DURATION and CONDITIONS:
1080 hours (45 days), Room temperature, panels submerged 50% to provide liquid and vapor phase testing.
Coupons, cut from plant applied Protecto 401™ Ceramic Epoxy lined pipe, were subjected to specific 1080 hour (45 day), 70°C partial submersion in a series of strong chemicals. The test solutions and results are tabulated below.
|
CHEMICAL SYSTEM |
RESULTS |
|
3% Sulfuric Acid |
Pass: Coating unaffected; Corrosion to opposite side of metal coupon. |
|
10% Sulfuric Acid |
Pass: Coating unaffected; Corrosion to opposite side of metal coupon. |
|
5% Sodium Hydroxide |
Pass: Coating unaffected. |
|
20% Sodium Hydroxide |
Pass: Coating unaffected. |
|
25% Sodium Hydroxide |
Pass: Coating unaffected. |
|
10% Hydrochloric Acid |
Pass: Coating unaffected; Heavy corrosion loss to opposite side of coupon. |
|
Gasoline |
Pass: Coating unaffected; Some discoloration of gasoline. |
|
Toluene |
Pass: Coating unaffected; Some discoloration of toluene. |
|
DI Water |
Pass: Coating unaffected. |
|
Hot Water (45 day @ 76°C) |
Pass: Coating unaffected. |
CERTIFIED:
Dr. George Mills
Date: 12 July 1994