PERMEANCE ASTM E-96
COATINGS RESEARCH GROUP, INC.
2340 Hamilton Avenue, Cleveland, Ohio 44114 U.S.A.
216-781-9122 * * * FAX 216-781-9239
DATE: March 10,1993
TO: Bill Setser
FROM: Phil Slifko
SUBJECT: Perm Rating of Indurall Sample Protecto 401
Procedure A of ASTM 96-66, described in Project 10-002 p 14-30 (February 1979), was used to determine the permeance of the submitted paint sample. Over a period of thirty days in our humidity cabinet, relative humidity (outside the cup) and temperature averaged 48.6% and 78.0°F (25.6°C), respectively. Glidden's Insul-aid was used as the control in this test. The permeance of the Protecto 401 (Q8-2401 [component A] blended with D8- 2401 [component B]) along with the control are shown in the following Table:
TABLE: Perm Rating of Test Coatings
|
COATING |
PROTECTO 401 |
GLIDDEN INSUL-AID |
|
DRY FILM THICKNESS (MILS) |
53.00 |
2.36 |
|
PERMS |
0.00 |
0.63 |
*All samples were run in duplicate and averaged for permeance.
Sincerely,
Phil Slifko