PERMEANCE ASTM E-96

COATINGS RESEARCH GROUP, INC.

2340 Hamilton Avenue, Cleveland, Ohio 44114 U.S.A.
216-781-9122 * * * FAX 216-781-9239

DATE: March 10,1993

TO: Bill Setser
FROM: Phil Slifko
SUBJECT: Perm Rating of Indurall Sample Protecto 401

Procedure A of ASTM 96-66, described in Project 10-002 p 14-30 (February 1979), was used to determine the permeance of the submitted paint sample. Over a period of thirty days in our humidity cabinet, relative humidity (outside the cup) and temperature averaged 48.6% and 78.0°F (25.6°C), respectively. Glidden's Insul-aid was used as the control in this test. The permeance of the Protecto 401 (Q8-2401 [component A] blended with D8- 2401 [component B]) along with the control are shown in the following Table:

TABLE: Perm Rating of Test Coatings

COATING

PROTECTO 401

GLIDDEN INSUL-AID

DRY FILM THICKNESS (MILS)

53.00

2.36

PERMS

0.00

0.63

*All samples were run in duplicate and averaged for permeance.

Sincerely,

Phil Slifko

 

 

 

 

 

Back to Table of Contents